Veyance Technologies, Inc.
Printer Friendly Version

Lightwing™ Lightering STS Hose

lightWingLG

APPLICATION:

Designed for the transfer of crude oil and petroleum based produced for ship to ship lightering service, under all types of service conditions. All sizes rated for vacuum. Maximum flow rate 70 ft/sec (21m/s).

TEMPERATURE: -22°F to 176°F (-30°C to 80°C)

CONSTRUCTION:

TUBE:
Code 541-432 Black Nitrile for up to 50% aromatic content

Code 541-718 Black nitrile with static dissipating properties for up to 60% aromatic content

REINFORCEMENT: Helix free, synthetic fabric, heavy duty wall

COVER: Black Wingprene (spiral cloth wrap finish)

HOSE DIMENSIONS:

Nominal Inside DiameterInside DiameterOutside DiameterWeight
mmin.mmmm(kg/m)
3001230538249.9
2501025433142.8
200820426828.9
150615320317.0
10041021439.7

PRESSURE RATING:

  • Minus 0.3 Bars (vacuum) to 17 Bars (250 psi)
  • Minimum burst pressuure of 86 Bars (1,250 psi)

ELECTRICAL CONTINUITY:

Code 541-432
Available in electrically continuous or discontinuous

Code 541-718
Available in electrically continuous or semi-continuous

  • Electrically continuous hose has an electrical resistance less than 0.75 ohms/meter
  • Electrically discontinuous assembly has an electrical resistance more than 25,000 ohms per assembly at 500 VDC
  • Electrically semi-continuous assembly has an electrical resistance at 500 VDC between 1,000 to 20,000 ohms per assembly

MINIMUM BEND RADIUS:

The hose will retain its shape under a bend radius of four times the hose diameter when empty or full. In the event the hose gets kinked, it will recover its shape without permanent damage to the hose.

 


Length and Weights:

length meters7.68.59.110
length ft25283032.5
diameterlbskglbskglbskglbskg
4248113268122281128297135
6433197467212490223518235
8715325773351812369861391
101073488115952712165531288585
121314597141564314836741567712

Flow Rates:

 Max flow rated based on 21m/sec max
diameterM3/HRbbl/HR
46003,800
61,3508,400
82,40015,200
103,80023,900
125,50034,400

RECOMMENDED FITTINGS:
Coupled with carbon steel built-in nipples with hot dip galvanized (HDG) flange. Standard flange supplied to bolt hole to ANSI-B16.5 class 150, Flat Face Slip-On (FFSO) or Lap Joint (floating), other specifications are available on demand. Available in Raise Face and Weld Neck type.

MATERIAL:
Flanges: ASTM A-105 (max carbon content 0.25%)
Nipples: ASTM A106 A or B, or API -5L, or ASTM A285C, or equivalent (max carbon content 0.23%). Other materials available on demand.

BRANDING:
LIGHTWINGTMLIGHTERING STS HELIX-FREE 15 BAR

DOCK HOSE RFID:
All of our lightering hose have factory embedded RFID InfoChips to improve hose management and make it easier than ever to comply with marine regulatory specifications. We have partnered with InfoChip® Systems, Inc. so that all of our lightering products deliver an innovative solution that streamlines hose identification, inspection, inventory and the certification process.

PACKAGING:
Chloroplast sheet wrap. Also available in corrugated plastic culvert packaging.

CUT LENGTHS:
Built to length.
Max length for closed container shipment 39’
Max length for North America land transport 51’

DESIGN SPECIFICATION:
LightwingTM Lightering Hose is designed in accordance with EN1765 L-15 and manufactured in accordance with ISO 9001 certified facility.

TESTING:
All hose is tested to Coast Guard requirements specified in the code of Federal Regulations, title 33, Chapter 1, Subpart C clause 154.500 and to OCIMF latest edition.

CERTIFICATION:
Hose supplied with hydrostatic test certification.

lightwing in use